6Y9B

Cryo-EM structure of trimeric human STEAP1 bound to three Fab120.545 fragments


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d17.684
f_angle_d0.526
f_chiral_restr0.042
f_bond_d0.004
f_plane_restr0.003
Sample
Trimeric human six-transmembrane epithelial antigen of the prostate (STEAP1) bound to three Fab-fragments of antibody mAb120.545
Sample Components
Fab-fragment 1 of antibody mAb120.545
Homo-trimeric STEAP1, chain a, b and c.
Fab Fragment 2 of antibody mAb120.545
Fab-fragment 3 of antibody mAb120.545
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE-PROPANE
Sample Vitrification Detailsblot 4 seconds, blotforce 0
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles169426
Reported Resolution (Å)2.97
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsFinal reconstruction was generated in Relion.
Refinement Type
Symmetry TypePOINT
Point SymmetryC3
Map-Model Fitting and Refinement
Id1 (6HCY)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value100.9
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)49.5
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TALOS ARCTICA
Minimum Defocus (nm)1000
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging DetailsData was collected on a 200 kV Talos Arctica, located at Utrecht University, the Netherlands.
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf1.18
MODEL FITTINGUCSF Chimera1.12
INITIAL EULER ASSIGNMENTRELION3.0
FINAL EULER ASSIGNMENTRELION3.1beta
CLASSIFICATIONRELION3.1beta
RECONSTRUCTIONRELION3.1beta
MODEL REFINEMENTPHENIX1.17.1-3660
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION616302Picking was performed in Relion.