3J40

Validated Near-Atomic Resolution Structure of Bacteriophage Epsilon15 Derived from Cryo-EM and Modeling


ELECTRON MICROSCOPY
Sample
Bacteriophage epsilon15
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK II
Cryogen NameETHANE
Sample Vitrification DetailsBlot before plunging into liquid ethane (FEI VITROBOT MARK II).
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles14000
Reported Resolution (Å)4.5
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsThe gold standard definition for the resolution estimate was adopted whereby the particle images were split into two subsets at the onset of image pro ...
Refinement TypeHALF-MAPS REFINED INDEPENDENTLY
Symmetry TypePOINT
Point SymmetryI
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeKODAK SO-163 FILM
Electron Dose (electrons/Å**2)17
Imaging Experiment1
Date of Experiment2007-01-03
Temperature (Kelvin)81
Microscope ModelJEOL 3200FSC
Minimum Defocus (nm)400
Maximum Defocus (nm)2700
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS4.1
Imaging ModeBRIGHT FIELD
Specimen Holder ModelJEOL 3200FSC CRYOHOLDER
Nominal Magnification50000
Calibrated Magnification53361
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
RECONSTRUCTIONEMAN1
RECONSTRUCTIONEMAN2
RECONSTRUCTIONjspr
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
per particle