4V4U
The quasi-atomic model of Human Adenovirus type 5 capsid
ELECTRON MICROSCOPY
Sample |
---|
HUMAN ADENOVIRUS TYPE 5 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | ZEISS PLUNGE FREEZER CRYOBOX |
Cryogen Name | ETHANE |
Sample Vitrification Details | LIQUID ETHANE |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 4100 |
Reported Resolution (Å) | 10 |
Resolution Method | |
Other Details | THE NUMBER OF ATOMS IN THIS STRUCTURE EXCEEDS THE MAXIMUM ALLOWED BY THE PDB FORMAT. IT HAS THEREFORE BEEN SPLIT ACROSS TWO PDB ENTRIES: 2BLD CONTAINS ... |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | I |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | RECIPROCAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | R-FACTOR, CORRELATION COEFFICIENT | ||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | METHOD--RIGID BODY REFINEMENT PROTOCOL--X-RAY |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | KODAK SO-163 FILM | ||||||||
Electron Dose (electrons/Å**2) | 10 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | 2003-10-01 |
Temperature (Kelvin) | 95 |
Microscope Model | FEI/PHILIPS CM200T |
Minimum Defocus (nm) | 100 |
Maximum Defocus (nm) | 250 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | 27500 |
Calibrated Magnification | 28600 |
Source | LAB6 |
Acceleration Voltage (kV) | 200 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
CTF CORRECTION | CTFMIX | |
MODEL FITTING | Situs | |
MODEL FITTING | URO | |
PARTICLE SELECTION | X3D | |
RECONSTRUCTION | EM3DR | |
RECONSTRUCTION | PFT | 2 |
RECONSTRUCTION | SPIDER |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
AMPLITUDE, PHASE TMV AND COMPARISON WITH X-RAY DATA |