5LKH
Cryo-EM structure of the Tc toxin TcdA1 in its pore state (obtained by flexible fitting)
ELECTRON MICROSCOPY
Sample |
---|
Structure of TcdA1 in pore state, determined in lipid nanodiscs |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | GATAN CRYOPLUNGE 3 |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 13000 |
Reported Resolution (Å) | 3.46 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | The density was filtered to its local resolution using localfilt (SPARX) and Remap. Although the density map has an average resolution of 3.46 A, the ... |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C5 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | |||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | Pseudoatomic model was obtained by flexible fitting after initial rigid body fitting of individual domains in Chimera. |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | FEI FALCON II (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 15.4 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | |
Maximum Defocus (nm) | |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | 59000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | Cs corrected microscope |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | EPU | |
CTF CORRECTION | CTFFIND | 4 |
MODEL FITTING | iMODFIT | |
MODEL FITTING | DireX | |
INITIAL EULER ASSIGNMENT | RELION | |
FINAL EULER ASSIGNMENT | RELION | |
RECONSTRUCTION | RELION |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 30061 | particles were picked manually |