6R9T
Cryo-EM structure of autoinhibited human talin-1
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 3IVF | |
experimental model | PDB | 1SJ8 | |
experimental model | PDB | 2L7A | |
experimental model | PDB | 2LQG | |
experimental model | PDB | 2L7N | |
experimental model | PDB | 2L10 | |
experimental model | PDB | 5IC1 | |
experimental model | PDB | 2KVP | |
experimental model | PDB | 3DYJ | |
experimental model | PDB | 2JSW |
Sample |
---|
Talin-1 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE-PROPANE |
Sample Vitrification Details | Blotted 4 seconds before plunging, blot force 4 |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 30438 |
Reported Resolution (Å) | 6.2 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (3IVF, 1SJ8, 2L7A, 2LQG, 2L7N, 2L10, 5IC1, 2KVP, 3DYJ, 2JSW) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | |||||
Overall B Value | 377 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 76.8 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | 2018-05-14 |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1000 |
Maximum Defocus (nm) | 3000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.62 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 130000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | SerialEM | 3.6 |
CTF CORRECTION | Gctf | 1.06 |
MODEL FITTING | Coot | 0.8.9.1 |
MODEL FITTING | UCSF Chimera | 1.13.1 |
INITIAL EULER ASSIGNMENT | cryoSPARC | 1 |
FINAL EULER ASSIGNMENT | RELION | 3.0 |
CLASSIFICATION | RELION | 3.0 |
RECONSTRUCTION | RELION | 3.0 |
MODEL REFINEMENT | PHENIX | 1.14-3260 |
MODEL FITTING | Amber | 18 |
PARTICLE SELECTION | Gautomatch | 0.56 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 1873975 |