3JAL

Cryo-EM structure of GMPCPP-microtubule co-polymerized with EB3


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg34.546
r_dihedral_angle_3_deg14.646
r_dihedral_angle_4_deg13.253
r_dihedral_angle_1_deg9.485
r_mcangle_it3.967
r_mcbond_it2.17
r_mcbond_other2.17
r_angle_refined_deg1.372
r_angle_other_deg0.942
r_chiral_restr0.08
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg34.546
r_dihedral_angle_3_deg14.646
r_dihedral_angle_4_deg13.253
r_dihedral_angle_1_deg9.485
r_mcangle_it3.967
r_mcbond_it2.17
r_mcbond_other2.17
r_angle_refined_deg1.372
r_angle_other_deg0.942
r_chiral_restr0.08
r_bond_refined_d0.008
r_gen_planes_refined0.005
r_bond_other_d0.002
r_gen_planes_other0.002
Sample
GMPCPP-microtubule co-polymerized with EB3
Sample Components
Alpha tubulin
Beta tubulin
EB3
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK II
Cryogen NameETHANE
Sample Vitrification DetailsBlot once for 4 seconds before plunging into liquid ethane (FEI VITROBOT MARK II).
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles
Reported Resolution (Å)3.5
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsIHRSR algorithm with microtubule-specific pseudo-helical symmetry applied
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise9.46
Angular Rotation27.7
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 (4k x 4k)
Electron Dose (electrons/Å**2)27.6
Imaging Experiment1
Date of Experiment2014-03-10
Temperature (Kelvin)90
Microscope ModelFEI TITAN
Minimum Defocus (nm)1000
Maximum Defocus (nm)3500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelGATAN LIQUID NITROGEN
Nominal Magnification27500
Calibrated Magnification27500
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
RECONSTRUCTIONEMAN1
RECONSTRUCTIONFREALIGN
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
CTFFIND4, each particle