6IAW

Structure of head fiber and inner core protein gp22 of native bacteriophage P68


ELECTRON MICROSCOPY
Sample
Staphylococcus phage P68
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Detailsblot time 2s; blot force -2; 3.6 ul of sample
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles28826
Reported Resolution (Å)3.8
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC5
Map-Model Fitting and Refinement
Id1 (6IAT)
Refinement SpaceREAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value
Fitting Procedure
DetailsThe refinement was conducted on rigid body fitted major capsid proteins and Arstotzka proteins obtained from related structure of 6IAT; EMD-4438. The ...The refinement was conducted on rigid body fitted major capsid proteins and Arstotzka proteins obtained from related structure of 6IAT; EMD-4438. The chains were fitted into hexon adjacent to portal of P68 capsid obtained from 5-fold symmetrized reconstruction. Subsequently, poly-alanine chains were manually built into densities corresponding to N-terminal part of head-fiber (chain IDs H,K,L) and C-terminal part of inner core protein (chain IDs X,Y,Z). The map was masked according to the related pdb in chimera, normalized and put into several rounds of a real space refinement in Phenix.
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)21
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1
Maximum Defocus (nm)3
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification75000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONEMAN22.1
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4.0
MODEL FITTINGCoot0.8.8
INITIAL EULER ASSIGNMENTRELION2.1
FINAL EULER ASSIGNMENTRELION2.1
CLASSIFICATIONRELION2.1
RECONSTRUCTIONRELION2.1
MODEL REFINEMENTPHENIXdev:3042
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION37218