2R6P
Fit of E protein and Fab 1A1D-2 into 24 angstrom resolution cryoEM map of Fab complexed with dengue 2 virus.
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 1THD |
Sample |
---|
Fab Fragment of MAb 1A1D-2 complexed with Dengue 2 virus |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | HOMEMADE PLUNGER |
Cryogen Name | ETHANE |
Sample Vitrification Details | SAMPLES WERE PREPARED AS THIN LAYERS OF VITREOUS ICE AND MAINTAINED AT LIQUID NITROGEN TEMPERATURE IN THE ELECTRON MICROSCOPE |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 2885 |
Reported Resolution (Å) | 24 |
Resolution Method | |
Other Details | THE COORDINATES IN THIS ENTRY CONTAIN CA ONLY |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | I |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (1THD) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | Using EMFIT | ||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | METHOD--place coordinates manually and then optimise position using program REFINEMENT PROTOCOL--rigid body |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | KODAK SO-163 FILM | ||||||||
Electron Dose (electrons/Å**2) | 2.39 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | 2007-03-21 |
Temperature (Kelvin) | 87 |
Microscope Model | FEI/PHILIPS CM200T |
Minimum Defocus (nm) | 2276 |
Maximum Defocus (nm) | 3373 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | 50000 |
Calibrated Magnification | 51040 |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 200 |
Imaging Details | low dose |
EM Software | ||
---|---|---|
Task | Software Package | Version |
MODEL FITTING | EMfit | |
RECONSTRUCTION | SPIDER | |
RECONSTRUCTION | Xmipp |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
phase flip |