☰ Navigation Tabs
Nucleoplasmic pre-60S intermediate of the Nog2 containing pre-rotation state from a SPB1 D52A strain
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 3JCT
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 13.2645 f_angle_d 0.5357 f_chiral_restr 0.0355 f_plane_restr 0.0042 f_bond_d 0.0024
Sample Nucleolar 60S intermediate purified with tags on Tif6 and Nog2 from a SPB1 D52A strain
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 534641 Reported Resolution (Å) 2.44 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 (3JCT) Refinement Space Refinement Protocol RIGID BODY FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 1.4
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 900 Maximum Defocus (nm) 2200 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 81000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION RELION IMAGE ACQUISITION SerialEM CTF CORRECTION Gctf INITIAL EULER ASSIGNMENT RELION FINAL EULER ASSIGNMENT RELION CLASSIFICATION RELION RECONSTRUCTION RELION
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE 925065