8X0D
Human FL Metabotropic glutamate receptor 5, mGlu5-5M with quisqualate and VU0424465, conformer 2
ELECTRON MICROSCOPY
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
r_dihedral_angle_3_deg | 16.522 |
r_long_range_B_refined | 16.044 |
r_long_range_B_other | 16.044 |
r_mcangle_it | 6.105 |
r_mcangle_other | 6.105 |
r_dihedral_angle_1_deg | 5.465 |
r_scangle_other | 5.303 |
r_dihedral_angle_2_deg | 4.012 |
r_mcbond_it | 3.335 |
r_mcbond_other | 3.335 |
Sample |
---|
Human FL Metabotropic glutamate receptor 5, mGlu5-5M |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | Blotting time of 5 seconds and blot force of 10 |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 41886 |
Reported Resolution (Å) | 3.5 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | RECIPROCAL | ||||
Refinement Protocol | OTHER | ||||
Refinement Target | |||||
Overall B Value | 95.3 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | FEI FALCON IV (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 50 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 500 |
Maximum Defocus (nm) | 1200 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 165000 |
Calibrated Magnification | 192572 |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | Images were collected with Aberration-free image shift and Fringe-free imaging with a Selectris energy filter in EFTEM mode |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | Topaz | |
IMAGE ACQUISITION | EPU | |
CTF CORRECTION | CTFFIND | 4.1.14 |
CTF CORRECTION | RELION | 4.0 |
CTF CORRECTION | cryoSPARC | |
MODEL FITTING | UCSF Chimera | 1.15 |
MODEL FITTING | Coot | 0.9.8.7 |
RECONSTRUCTION | cryoSPARC | |
MODEL REFINEMENT | PHENIX | 1.20.1-4487 |
MODEL REFINEMENT | REFMAC | 5.8.0411 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 4481289 |