8X0E
Human FL Metabotropic glutamate receptor 5, mGlu5-5M with agonist and PAM, W785A mutant
ELECTRON MICROSCOPY
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
r_long_range_B_refined | 23.868 |
r_long_range_B_other | 23.868 |
r_dihedral_angle_3_deg | 17.5 |
r_scangle_other | 12.759 |
r_mcangle_it | 11.434 |
r_mcangle_other | 11.433 |
r_scbond_it | 7.187 |
r_scbond_other | 7.186 |
r_mcbond_it | 6.667 |
r_mcbond_other | 6.667 |
Sample |
---|
Thermostabilised full length human mGluR5, W785A mutant |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | Blot force was set to 0 |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 188960 |
Reported Resolution (Å) | 3.4 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | RECIPROCAL | ||||
Refinement Protocol | OTHER | ||||
Refinement Target | |||||
Overall B Value | 183.8 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | FEI FALCON III (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 28.25 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1800 |
Maximum Defocus (nm) | 2800 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 75000 |
Calibrated Magnification | 130841 |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | Gautomatch | 0.56 |
IMAGE ACQUISITION | EPU | 2.10.0.5REL |
CTF CORRECTION | CTFFIND | 4.1.14 |
CTF CORRECTION | RELION | 4.0.1 |
CTF CORRECTION | cryoSPARC | 4.3.0 |
MODEL FITTING | UCSF Chimera | 1.15 |
MODEL FITTING | Coot | 0.9.8.7 |
INITIAL EULER ASSIGNMENT | RELION | 4.0.1 |
FINAL EULER ASSIGNMENT | cryoSPARC | 4.3.0 |
RECONSTRUCTION | cryoSPARC | 4.3.0 |
MODEL REFINEMENT | PHENIX | 1.20.1-4487 |
MODEL REFINEMENT | REFMAC | 5.8.0411 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 783666 | The particles were extract from two batches of data collection |