3JBG
Complex of poliovirus with VHH PVSS21E
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 3QXU |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
r_dihedral_angle_2_deg | 22.797 |
r_dihedral_angle_3_deg | 7.663 |
r_dihedral_angle_4_deg | 6.888 |
r_angle_refined_deg | 1.753 |
r_dihedral_angle_1_deg | 1.674 |
r_chiral_restr | 0.125 |
r_bond_refined_d | 0.008 |
r_gen_planes_refined | 0.004 |
Sample |
---|
Nanobody PVSS8A in complex with poliovirus P1/Mahoney |
Sample Components |
Human poliovirus 1 |
PVSS21E |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | HOMEMADE PLUNGER |
Cryogen Name | ETHANE |
Sample Vitrification Details | Blotted for 4 seconds before plunging into liquid ethane (homemade plunger). |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 24717 |
Reported Resolution (Å) | 3.8 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | (Single particle details: The particles were processed using Frealign.) (Single particle--Applied symmetry: I) |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | I |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (3QXU) | ||||
Refinement Space | RECIPROCAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | ML agreement with Fourier amplitudes and phases | ||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | REFINEMENT PROTOCOL--flexible DETAILS--Using stereochemically and icosahedrally restrained maximum likelihood refinement in REFMAC5, a representative ... |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 25 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | 2013-11-27 |
Temperature (Kelvin) | 80 |
Microscope Model | FEI POLARA 300 |
Minimum Defocus (nm) | -1400 |
Maximum Defocus (nm) | -4000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.26 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | OTHER |
Nominal Magnification | 23000 |
Calibrated Magnification | 25381 |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | Gatan K2 operated in Super-resolution mode |
EM Software | ||
---|---|---|
Task | Software Package | Version |
MODEL FITTING | Coot | |
MODEL FITTING | REFMAC | 5 |
MODEL FITTING | SPDBV | |
RECONSTRUCTION | FREALIGN |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
per particle |