4UFT
Structure of the helical Measles virus nucleocapsid
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 2WJ8 |
Sample |
---|
RECOMBINANT MEASLES NUCLEOPROTEIN-RNA HELICAL ASSEMBLY (NUCLEOCAPSID) |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 228165 |
Reported Resolution (Å) | 4.3 |
Resolution Method | |
Other Details | SUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD -2867. (DEPOSITION ID: 13046). |
Refinement Type | |
Symmetry Type | HELICAL |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (2WJ8) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | METHOD--FLEXIBLE REFINEMENT PROTOCOL--X-RAY |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | KODAK SO-163 FILM | ||||||||
Electron Dose (electrons/Å**2) |
Imaging Experiment | 1 |
---|---|
Date of Experiment | 2013-07-01 |
Temperature (Kelvin) | |
Microscope Model | FEI TECNAI F30 |
Minimum Defocus (nm) | 800 |
Maximum Defocus (nm) | 3500 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | 59000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | SPECIAL CARE WAS TAKEN TO PERFORM A COMA-FREE ALIGNMENT OF THE MICROSCOPE |
EM Software | ||
---|---|---|
Task | Software Package | Version |
MODEL FITTING | Coot | |
MODEL FITTING | MODELLER | |
MODEL FITTING | PHENIX | |
MODEL FITTING | UCSF Chimera | |
RECONSTRUCTION | SPRING |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
EACH PARTICLE |