4UPF
Assembly principles of the unique cage formed by the ATPase RavA hexamer and the lysine decarboxylase LdcI decamer
ELECTRON MICROSCOPY
Sample |
---|
COMPLEX BETWEEN A DECAMER OF INDUCIBLE LYSINE DECARBOXYLASE LDCI AND TEN LARA DOMAINS OF THE ATPASE RAVA |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK III |
Cryogen Name | ETHANE |
Sample Vitrification Details | VITRIFICATION 1 -- CRYOGEN- ETHANE, HUMIDITY- 100, TEMPERATURE- 91, INSTRUMENT- FEI VITROBOT MARK III, METHOD- BLOT FOR 2 SECONDS BEFORE PLUNGING |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 23540 |
Reported Resolution (Å) | 7.5 |
Resolution Method | |
Other Details | CROSS-COMMON LINE, PROJECTION MATCHING SUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD-2681. (DEPOSITION ID: 12595). |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | D5 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (3N75, 3NBX) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | Cross-correlation coefficient | ||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | METHOD--FLEXIBLE FOR 3N75, RIGID FOR 3NBX REFINEMENT PROTOCOL--X-RAY |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN ULTRASCAN 4000 (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 20 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | 2012-09-14 |
Temperature (Kelvin) | 91 |
Microscope Model | FEI TECNAI F30 |
Minimum Defocus (nm) | 1500 |
Maximum Defocus (nm) | 2700 |
Minimum Tilt Angle (degrees) | -0.1 |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | 51660 |
Calibrated Magnification | 51660 |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | AUTOMATIC DATA ACQUISITION WITH FEI EPU SOFTWARE |
EM Software | ||
---|---|---|
Task | Software Package | Version |
CTF CORRECTION | CTFFIND | 3 |
MODEL FITTING | Flex-EM | |
MODEL FITTING | Situs | |
PARTICLE SELECTION | EMAN | |
RECONSTRUCTION | EMAN | |
RECONSTRUCTION | FPM | |
RECONSTRUCTION | IMAGIC | |
RECONSTRUCTION | SPIDER |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING |