4V7C

Structure of the Ribosome with Elongation Factor G Trapped in the Pre-Translocation State (pre-translocation 70S*tRNA structure)


ELECTRON MICROSCOPY
Sample
Pre-translocation ribosome bound to A/P, P/E hybrid state tRNA
Sample Components
70S ribosome
Transfer RNA
Messenger RNA
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK II
Cryogen NameETHANE
Sample Vitrification DetailsFreshly glow-disharged grids were loaded into an FEI Mark II Vitrobot and equilibrated to 95% relative humidity at 22 degrees Celsius. 2 microliters o ...Freshly glow-disharged grids were loaded into an FEI Mark II Vitrobot and equilibrated to 95% relative humidity at 22 degrees Celsius. 2 microliters of sample was applied through the side port, blotted for 7 seconds with a positional offset of 2, and plunged into liquid ethane.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles85115
Reported Resolution (Å)7.6
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsRefinement included data to 12 Angstrom resolution to limit FSC bias. See primary citation Supplementary Information for details. (Single particle det ...Refinement included data to 12 Angstrom resolution to limit FSC bias. See primary citation Supplementary Information for details. (Single particle details: Refinement and 3D classification performed by Frealign) (Single particle--Applied symmetry: C1)
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (4GD1)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetCross-correlation
Overall B Value
Fitting Procedure
DetailsREFINEMENT PROTOCOL--rigid body DETAILS--Chain Y not used in refinement
Data Acquisition
Detector TypeFEI FALCON I (4k x 4k)
Electron Dose (electrons/Å**2)30
Imaging Experiment1
Date of Experiment2012-11-02
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1150
Maximum Defocus (nm)6950
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS0.01
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification133333
Calibrated Magnification134615
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
CTF CORRECTIONCTFFIND3
MODEL FITTINGCNS
MODEL FITTINGUCSF Chimera
RECONSTRUCTIONEMAN2
RECONSTRUCTIONFREALIGN
RECONSTRUCTIONIMAGIC
RECONSTRUCTIONRSAMPLE
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
CTFFIND3, FREALIGN per micrograph