Cryo-EM structure of yeast reconstituted Lso2 bound to 80S ribosomes
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 14.1291 f_angle_d 0.8993 f_chiral_restr 0.0506 f_bond_d 0.0106 f_plane_restr 0.006
Sample Lso2-80S ribosome Sample Components 80S ribosome Lso2
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 88523 Reported Resolution (Å) 3.4 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol RIGID BODY FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type FEI FALCON II (4k x 4k) Electron Dose (electrons/Å**2) 28
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) Maximum Defocus (nm) Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version CTF CORRECTION CTFFIND MODEL FITTING Coot INITIAL EULER ASSIGNMENT RELION FINAL EULER ASSIGNMENT RELION CLASSIFICATION RELION RECONSTRUCTION RELION MODEL REFINEMENT PHENIX
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION