9BEI
Cryo-EM structure of synthetic claudin-4 complex with Clostridium perfringens enterotoxin C-terminal domain, sFab COP-2, and Nanobody
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 7DTM | |
in silico model | AlphaFold |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 7.383 |
f_angle_d | 0.734 |
f_chiral_restr | 0.046 |
f_plane_restr | 0.006 |
f_bond_d | 0.003 |
Sample |
---|
Synthetic human claudin-4 complex with Clostridium perfringens enterotoxin C-terminal domain, sFab COP-2, and nanobody against COP-2 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | LEICA EM GP |
Cryogen Name | ETHANE |
Sample Vitrification Details | 3.5 microL of complex was applied onto grids and blotted for 3 s at 4 degrees C under 100 percent humidity then plunge frozen into liquid ethane coole ... |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 21296 |
Reported Resolution (Å) | 4.16 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (7DTM, 7DTM, 7DTM) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | |||||
Overall B Value | 322 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | FEI FALCON IV (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 49.4 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | TFS GLACIOS |
Minimum Defocus (nm) | 400 |
Maximum Defocus (nm) | 2000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 120000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 200 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | cryoSPARC | 4.4.1 |
IMAGE ACQUISITION | EPU | |
CTF CORRECTION | cryoSPARC | 4.4.1 |
MODEL FITTING | PHENIX | 1.20.1-4487 |
MODEL REFINEMENT | PHENIX | 1.20.1-4487 |
INITIAL EULER ASSIGNMENT | cryoSPARC | 4.4.1 |
FINAL EULER ASSIGNMENT | cryoSPARC | 4.4.1 |
CLASSIFICATION | cryoSPARC | 4.4.1 |
RECONSTRUCTION | cryoSPARC | 4.4.1 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 1848208 |