9F5P
Poliovirus type 2 (strain MEF-1) stabilised virus-like particle (PV2 SC6b) from an insect cell expression system.
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 1EAH |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 11.537 |
f_angle_d | 0.561 |
f_chiral_restr | 0.045 |
f_bond_d | 0.005 |
f_plane_restr | 0.004 |
Sample |
---|
Poliovirus 2 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE-PROPANE |
Sample Vitrification Details | 4 ul of sample blotted for 3.5 seconds with -15 blot force on FEI Vitrobot mark IV. |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 3149 |
Reported Resolution (Å) | 2.6 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | Post-processing was applied with a b-factor of -52.2 A2 in RELION. |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | I |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (1EAH) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | Cross-correlation coefficient | ||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | Initial model was rigid body fitted using UCSF chimera and Coot. Global minimization and B-factor refinement was performed in real space using pheni ... |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 35 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 800 |
Maximum Defocus (nm) | 2300 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | DARK FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | |
Calibrated Magnification | 47170 |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | Preliminary grid screening was performed on a Glacios 200 kV microscope. |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | crYOLO | |
CTF CORRECTION | CTFFIND | 4.1 |
MODEL FITTING | UCSF Chimera | 1.16 |
MODEL FITTING | Coot | 0.9.6 |
INITIAL EULER ASSIGNMENT | RELION | 3.1.1 |
FINAL EULER ASSIGNMENT | RELION | 3.1.1 |
CLASSIFICATION | RELION | 3.1.1 |
RECONSTRUCTION | RELION | 3.1.1 |
MODEL REFINEMENT | PHENIX | 1.20.1_4487-000 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 11032 | Particle picking was performed with crYOLO. |